IMPACT COUPLER · Bolt-fastened rebar coupler
One pull of the impact wrench,
a slip-free rebar splice.
IMPACT COUPLER is structural technology, not just a material. No flame, no end threading, no special equipment: tighten the bolt with a standard impact tool and axial tension pre-compresses the rebar, blocking initial slip.
Why a new splice now
Is rebar splicing on your site good enough?
Fire and explosion risk
Gas pressure welding carries fire, explosion and heat-affected-zone weakening risks. Under Korea's Serious Accidents Punishment Act, flame-free methods are urgent.
Shortage of skilled workers
Workers in their 20s and 30s fell from 56.6% of Korea's construction workforce in 1995 to 21.6% in 2024, with a shortfall estimated at about 350,000 people.
Stricter seismic standards
KCI-ST103:2026 tightens dynamic performance evaluation of splices. Existing couplers with inconsistent fastening struggle to comply.
Waste from lap splices
Lap splices overlapping 600 mm or more waste about 15% of rebar — over KRW 120 billion a year — and congested bars cause poor concrete filling.
How it works
Turning impact into tension.
A pre-tensioning structure.
Rotational impact energy from the wrench becomes axial tension that physically pre-compresses the rebar. Multi-point bolt pressure and a radial expansion mechanism lock the rebar ribs and grippers together with zero play, blocking the slip that occurs when load is first applied.
3 related patent applications (Feb 2026) · axial tension pressing · radial expansion mechanism
-
STEP 1
Insert lower bar
No thread rolling — insert rebar exactly as delivered from the mill.
-
STEP 2
Insert upper bar
Insert the opposite bar. Works for vertical, horizontal and tie bars alike.
-
STEP 3
Fasten bolt (done)
5–10 seconds with a standard ~3 kg impact tool. The reference torque (N·m) confirms completion on the spot.


Comparison
Fewer parts, more strength, more speed.
| Item | Lap splice | Threaded | Gas pressure welding | Wedge | IMPACT COUPLER |
|---|---|---|---|---|---|
| Material | - | S45C | - | S45C | SCM440 |
| Rebar grade | SD400 | SD500 | SD400 | SD500 | SD600 |
| Tensile strength | - | 570~700 MPa | - | 570~700 MPa | 850~1,000 MPa (target) |
| Installation time | 2+ days | 10–30 min | 10–20 min | 5–10 min | Under 1 min |
| Fire risk | None | None | Very high | None | None |
| Skill dependency | High | High | Very high | Medium | Not needed |
| Quality control | Visual | Manual torque | Manual | Manual | Digital torque mapping |
Time per splice is from the product catalog; the table is based on the 2026 business plan. IMPACT COUPLER tensile strength is a development target with SCM440.
Specifications
Ready for SD600 ultra-high-strength rebar with SCM440 alloy steel.
Plain carbon steel (S45C) struggles to stay uniformly strong through large diameters. We quench (830–870 °C, oil) and temper (500–650 °C) Cr-Mo alloy steel SCM440 for both strength and toughness.

- Fastening
- High-strength axial tension bolt fastening (pre-tensioning)
- Rebar
- SD400~SD600 · D13~D43 (10 sizes)D22 and D25 prototypes first; other sizes to follow
- Material
- SCM440 alloy steel, Q/T heat-treated · HRC 32+
- Tensile strength
- Prototype measured at 611 N/mm²Target 850–1,000 MPa with SCM440
- Install & seismic
- Under 1 min · targeting KCI-ST103 seismic grade 1Residual slip ≤ 0.1 mm, 30+ load cycles
- Machining
- NC/CNC precision machining, ±0.05 mm tolerance
Size chart
Ten sizes from D13 to D43
| Rebar size | D13 | D16 | D19 | D22 | D25 | D29 | D32 | D35 | D38 | D43 |
|---|---|---|---|---|---|---|---|---|---|---|
| Outer dia. D (mm) | 35 | 40 | 48 | 55 | 60 | 68 | 70 | 75 | 80 | 86 |
| Length L (mm) | 92 | 105 | 130 | 146 | 163 | 182 | 197 | 205 | 212 | 220 |
Dimensions from the product catalog; they may change in mass production.
Performance & certification
We publish what is proven and what is still being tested — separately.
Proven Results so far
- Tensile test: 611 N/mm² measuredGyeongsang National University, Dept. of Civil Engineering · above the KS B 0802 reference of 560 N/mm²
- 3 patent applications (Feb 2026)Impact-fastened axial tension pressing · impact screw-fastened radial expansion · radial expansion mechanism and installation method
In progress Certification roadmap
- KS B 0802 accredited test reportTensile strength report from an accredited laboratory
- KCI-ST103:2026 seismic grade 1Residual slip ≤ 0.1 mm, 30+ cyclic loads
- ISO 15835 · Korean New Construction TechnologyCertifications for export and public procurement


Test Reports →
Download published test reports as PDF.
Applications
From apartments to power plants — wherever the splice matters.
Apartments & commercial buildings
Fast, uniform splicing for mat foundations and columns
Turbine foundations & cooling towers
Structures under constant vibration, dynamic load and fatigue
LNG storage tanks
Special structures for cryogenic and airtight conditions
Bridges, ports & tunnels
Infrastructure and coastal structures with mandatory seismic design
KORINGO Co., Ltd.
Rebar splicing technology for safer, more efficient sites.
IMPACT COUPLER is KORINGO's construction technology business. KORINGO also runs a native-language Korean learning platform and a platform development business.
Request a Quote
Tell us about your site and we will send a quote with the right sizes.
- Phone
- +82 55-759-1026
- kimgk1026@gmail.com
Requesting a quote takes a minute
Leave the rebar size, estimated quantity and site location, and we will contact you within 1–2 business days. Drawings or quantity sheets help us be precise.
Request a quote